Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Anesth Analg ; 138(1): 123-133, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38100804

RESUMO

BACKGROUND: Guidelines for the evaluation and grading of diastolic dysfunction are available for transthoracic echocardiography (TTE). Transesophageal echocardiography (TEE) is used for this purpose intraoperatively but the level of agreement between these 2 imaging modalities for grading diastolic dysfunction is unknown. We assessed agreement between awake preoperative TTE and intraoperative TEE for grading diastolic dysfunction. METHODS: In 98 patients undergoing cardiac surgery, key Doppler measurements were obtained using TTE and TEE at the following time points: TTE before anesthesia induction (TTEawake), TTE following anesthesia induction (TTEanesth), and TEE following anesthesia induction (TEEanesth). The primary endpoint was grade of diastolic dysfunction categorized by a simplified algorithm, and measured by TTEawake and TEEanesth, for which the weighted κ statistic assessed observed agreement beyond chance. Secondary endpoints were peak early diastolic lateral mitral annular tissue velocity (e'lat) and the ratio of peak early diastolic mitral inflow velocity (E) to e'lat (E/e'lat), measured by TTEawake and TEEanesth, were compared using Bland-Altman limits of agreement. RESULTS: Disagreement in grading diastolic dysfunction by ≥1 grade occurred in 43 (54%) of 79 patients and by ≥2 grades in 8 (10%) patients with paired measurements for analysis, yielding a weighted κ of 0.35 (95% confidence interval [CI], 0.19-0.51) for the observed level of agreement beyond chance. Bland-Altman analysis of paired data for e'lat and E/e'lat demonstrated a mean difference (95% CI) of 0.51 (-0.06 to 1.09) and 0.70 (0.07-1.34), respectively, for measurements made by TTEawake compared to TEEanesth. The percentage (95% CI) of paired measurements for e'lat and E/e'lat that lay outside the [-2, +2] study-specified boundary of acceptable agreement was 36% (27%-48%) and 39% (29%-51%), respectively. Results were generally robust to sensitivity analyses, including comparing measurements between TTEawake and TTEanesth, between TTEanesth and TEEanesth, and after regrading diastolic dysfunction by the American Society of Echocardiography (ASE)/European Association of CardioVascular Imaging (EACVI) algorithm. CONCLUSIONS: There was poor agreement between TTEawake and TEEanesth for grading diastolic dysfunction by a simplified algorithm, with disagreement by ≥1 grade in 54% and by ≥2 grades in 10% of the evaluable cohort. Future studies, including comparing the prognostic utility of TTEawake and TEEanesth for clinically important adverse outcomes that may be a consequence of diastolic dysfunction, are needed to understand whether this disagreement reflects random variability in Doppler variables, misclassification by the changed technique and physiological conditions of intraoperative TEE, or the accurate detection of a clinically relevant change in diastolic dysfunction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Transesofagiana , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos , Algoritmos
2.
J Card Fail ; 28(1): 83-92, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34425221

RESUMO

BACKGROUND: There is a paucity of data on depression, anxiety and post-traumatic stress disorder after left ventricular assist device (LVAD) implantation. We designed an observational study to integrate these with functional capacity and health-related quality of life (HR-QOL) in surviving LVAD patients. METHODS AND RESULTS: Consenting patients between 1 month and 9 years after LVAD implantation (n = 121) were screened for functional capacity (World Health Organization Disability Assessment Schedule 2.0 [WHODAS 2.0)]); HR-QOL (European Quality of Life [EQ-5D] and Visual Assessment Scales [EQ-VAS]), depression (Patient Health Questionnaire [PHQ-9], anxiety (Generalized Anxiety Disorder Scale [GAD-7]) and post-traumatic stress disorder (Impact of Event Scale Revised [IES-R]). Of the 94% of patients who consented, 34.7% reported impaired functional capacity (WHODAS 2.0 score of ≥25%), 23.1%-34.7% HR-QOL problems (domain EQ-5D of ≥3), 10.7% "poor health" (EQ-VAS of ≤40), 14.9% depression (PHQ-9 of >14), 11.7% suicidal ideation and 17.5% anxiety (GAD-7 of >10). Among these patients, 23.5% had a positive screen for post-traumatic stress disorder (IES-R of ≥24). An EQ-VAS of 80 or greater predicted good functional capacity (P < .001). CONCLUSIONS: One-third of discharged LVAD patients reported impaired function, HR-QOL, and psychological issues. A standardized evaluation before and after LVAD implantation could facilitate psychologic prehabilitation, inform decision-making, and identify indications for mental health intervention.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Transtornos de Estresse Pós-Traumáticos , Assistência ao Convalescente , Ansiedade/diagnóstico , Ansiedade/epidemiologia , Ansiedade/etiologia , Depressão/epidemiologia , Depressão/etiologia , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Coração Auxiliar/psicologia , Humanos , Alta do Paciente , Qualidade de Vida , Transtornos de Estresse Pós-Traumáticos/epidemiologia , Transtornos de Estresse Pós-Traumáticos/etiologia
3.
J Heart Lung Transplant ; 39(1): 53-61, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31636045

RESUMO

BACKGROUND: A donor arterial PO2/FiO2 (P/F ratio) of less than the 300 threshold would frequently result in either exclusion of the donor or placement of the lungs on ex vivo lung perfusion (EVLP). The aim was to investigate the veracity of the P/F ratio threshold of 300 for donor lung acceptability. METHODS: In 93 brain dead lung donors, arterial blood gases were drawn in the intensive care unit (ICU) just before procurement and each of the 4 donor pulmonary veins in the operating room (OR). No donor lungs were rejected for transplantation based on the last ICU or OR P/F ratio, and EVLP was not used. The recipients were followed up 6 and 12 months following transplantation. RESULTS: There were 93 recipients of bilateral lung transplantation. An arterial P/F ratio of < 300 was largely driven by a low P/F ratio in the lower lobes. There were no differences between the recipients receiving donor lungs where the ICU P/F ratio was < 300 compared with ≥ 300 in the time to extubation, grade of primary graft dysfunction, pulmonary function at 6 and 12 months, and 12-month survival. CONCLUSIONS: From this study:(1) If a donor P/F threshold of 300 was adhered to, 36% would have been rejected, and (2) The donor P/F ratio threshold of 300 is excessively conservative and results in the wastage of donor lungs and the application of unnecessary EVLP.


Assuntos
Circulação Extracorpórea/métodos , Sobrevivência de Enxerto/fisiologia , Transplante de Pulmão/métodos , Pulmão/metabolismo , Preservação de Órgãos/métodos , Perfusão/métodos , Doadores de Tecidos , Adulto , Feminino , Seguimentos , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
J Card Surg ; 33(7): 412-415, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29921031

RESUMO

A 27-year-old female with Eisenmenger's syndrome underwent closure of a patent ductus arteriosus, closure of a perimembranous ventricular septal defect and mid muscular defect and bilateral lung transplantation. Her immediate postoperative course was complicated by severe right ventricular outflow tract (RVOT) obstruction resulting in hemodynamic collapse, a condition described as suicide right ventricle. The patient was placed on central Veno-Arterial Extra-Corporeal Membrane Oxygenation as a bridge to the relief of RVOT obstruction which included a right ventricular outflow muscle resection and a right ventricle outflow tract patch. The patient made an uneventful recovery.


Assuntos
Anormalidades Múltiplas/cirurgia , Ventrículos do Coração/fisiopatologia , Pneumopatias/cirurgia , Transplante de Pulmão/métodos , Pulmão/irrigação sanguínea , Complicações Pós-Operatórias/fisiopatologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto , Permeabilidade do Canal Arterial/cirurgia , Complexo de Eisenmenger/cirurgia , Oxigenação por Membrana Extracorpórea/métodos , Feminino , Comunicação Interventricular/cirurgia , Hemodinâmica , Humanos , Complicações Pós-Operatórias/terapia , Índice de Gravidade de Doença , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/terapia
5.
Heart Lung ; 44(1): 50-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25453391

RESUMO

OBJECTIVES: To measure the impact of intermittent positive pressure ventilation (IPPV) on diastolic pulmonary arterial pressure (dPAP) and pulmonary pulse pressure in patients with advanced COPD. BACKGROUND: The physiological effects of raised intrathoracic pressures upon the pulmonary circulation have not been fully established. METHODS: 22 subjects with severe COPD receiving IPPV were prospectively assessed with pulmonary and radial arterial catheterization. Changes in dPAP were assessed from end-expiration to early inspiration during low and high tidal volume ventilation. RESULTS: Inspiration during low tidal volume IPPV increased the median [IQR] dPAP by 3.9 [2.5-4.8] mm Hg (P < 0.001). During high tidal volume, similar changes were observed. The IPPV-associated change in dPAP was correlated with baseline measures of PaO2 (rho = 0.65, P = 0.005), pH (rho = 0.64, P = 0.006) and right atrial pressure (rho = -0.53, P = 0.011). CONCLUSIONS: In severe COPD, IPPV increases dPAP and reduces pulmonary pulse pressure during inspiration.


Assuntos
Pressão Arterial/fisiologia , Ventilação com Pressão Positiva Intermitente , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Idoso , Pressão Sanguínea/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/metabolismo , Estudos Prospectivos , Circulação Pulmonar/fisiologia , Doença Pulmonar Obstrutiva Crônica/terapia , Volume de Ventilação Pulmonar/fisiologia
6.
J Heart Lung Transplant ; 33(11): 1139-48, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25016922

RESUMO

BACKGROUND: Primary graft dysfunction (PGD) remains a significant problem after lung transplantation. Data from animal and clinical studies suggest that remote ischemic conditioning (RIC) may reduce ischemia-reperfusion injury in solid organ transplantation. METHODS: A pilot randomized controlled trial of 60 patients undergoing bilateral sequential lung transplantation assessed the utility of RIC in attenuating PGD. Treated recipients underwent 3 cycles of lower limb ischemic conditioning before allograft reperfusion. The primary outcome measure was a comparison of the partial pressure of arterial oxygen/fraction of inspired oxygen ratio (P/F ratio) between treatment groups. RESULTS: No adverse effects of tourniquet application were observed. The mean lowest P/F ratio during the first 24 hours after transplantation was 271.3 mm Hg in the treatment arm vs 256.1 mm Hg in the control arm (p = 0.46). PGD grade and severity and the rate of acute rejection also showed a tendency to favor the treatment arm. Sub-group analysis demonstrated a significant benefit of treatment in patients with a primary diagnosis of restrictive lung disease, a group at high risk for the development of PGD. RIC was not accompanied by systemic release of high-molecular-weight group box 1. Levels of cytokines, high-molecular-weight group box 1, and endogenous secretory receptor for advanced glycation end products peaked within 2 hours after reperfusion and likely reflected donor organ quality rather than an effect of RIC. CONCLUSIONS: RIC did not significantly improve P/F ratios or PGD in this randomized controlled trial. However, encouraging results in this small study warrant a large multicenter trial of RIC in lung transplantation.


Assuntos
Precondicionamento Isquêmico/métodos , Transplante de Pulmão/métodos , Método Duplo-Cego , Estudos de Viabilidade , Feminino , Humanos , Precondicionamento Isquêmico/efeitos adversos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos
7.
Pediatr Transplant ; 17(8): E182-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24164831

RESUMO

To describe our experience to date of four children with end-stage lung disease who have been bridged with ECMO to successful lung transplantation in our institution. Between March 2006 and June 2012, a total of 21 pediatric patients successfully underwent lung transplantation within The Alfred's lung transplantation program. This included four children who were bridged on ECMO prior to transplantation according to the "ECMO bridge to transplant" protocol and whose clinical notes and outcomes were reviewed. Lung transplantation is an established life-saving treatment for patients with severe lung disease, but remains limited due to scarcity of suitable donor organs. This is a particular issue in the pediatric setting, where the smaller child waits disproportionately longer compared with adult patients for size-matched donor lungs. As ECMO has become more widely accepted, its use as a bridge to lung transplantation in pediatric patients with severe acute lung injury or end-stage chronic lung disease has been considered. The medical notes from the four pediatric patients were retrospectively reviewed. Our report describes excellent short- and medium-term outcomes in a small number of children who have been bridged to transplant on ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Pneumopatias/terapia , Transplante de Pulmão , Lesão Pulmonar Aguda/terapia , Adolescente , Criança , Estudos de Coortes , Fibrose Cística/terapia , Dispneia/terapia , Evolução Fatal , Feminino , Humanos , Pulmão/cirurgia , Resultado do Tratamento
8.
J Heart Lung Transplant ; 29(4): 439-44, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20044276

RESUMO

BACKGROUND: Cadaveric lobar lung transplantation (CLLTx) represents a potential opportunity to address the bias against smaller recipients, especially children, on transplant waiting lists. The widespread use of CLLTx is hindered by the paucity of outcome data with respect to early complications and long-term lung function and survival. METHODS: We looked at the long-term outcomes in 9 patients undergoing CLLTx since May 2003, including early surgical complications, pulmonary function tests, and survival. Patients were analyzed by whether the decision to perform CLLTx was elective (made at the time of listing) or emergent (surgical decision). RESULTS: The incidence of early complications in the entire group was low, with the most common being atrial arrhythmias and prolonged thoracostomy tube. Lung function at 1 and 2 years (mean forced expiratory volume in 1 second % predicted +/- standard deviation of 73 +/- 18 and 60.5 +/- 27, respectively) was equivalent to living lobar transplant results. Overall survival was similar to 199 patients who received conventional cadaveric LTx during the same period. CONCLUSION: This study suggests that CLLTx has a low complication rate with acceptable lung function and long-term survival, especially in cases where consideration has been given to CLLTx at the time of listing. CLLTx warrants consideration more often for patients of smaller physique to improve their chance of receiving LTx.


Assuntos
Cadáver , Transplante de Pulmão/fisiologia , Pulmão/fisiologia , Alocação de Recursos/métodos , Obtenção de Tecidos e Órgãos/métodos , Adolescente , Adulto , Idoso , Tamanho Corporal , Criança , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Transplante de Pulmão/mortalidade , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Testes de Função Respiratória , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Listas de Espera , Adulto Jovem
9.
Med J Aust ; 189(3): 173-5, 2008 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-18673110

RESUMO

Two children with advanced lung disease underwent successful cadaveric bilateral lobar lung transplantation, using lungs "cut down" from deceased adult donors - the first reported use of the technique in Australia. This approach, while it cannot address the lack of donor organs, may enable us to redress any size bias limiting paediatric lung transplantation.


Assuntos
Transplante de Pulmão/métodos , Transplante de Pulmão/estatística & dados numéricos , Doadores de Tecidos/provisão & distribuição , Adolescente , Adulto , Austrália , Cadáver , Criança , Seleção do Doador , Feminino , Sobrevivência de Enxerto , Humanos , Pneumonectomia , Insuficiência Respiratória/cirurgia , Transplante Homólogo/métodos
10.
J Heart Lung Transplant ; 27(5): 479-85, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18442712

RESUMO

BACKGROUND: The VentrAssist (VA) is a novel, continuous flow left ventricular assist device (LVAD). The purpose of this trial was to investigate the safety and efficacy of the VA in elderly patients with end-stage heart failure. METHODS: In this prospective trial, patients requiring circulatory support either as destination therapy (DT) or as a bridge to transplant (BTT) were implanted with a VA device. RESULTS: Between June 2003 and August 2006, 9 elderly patients (mean age 65 years) were implanted. The median support time was 454 (range 73 to 977) days for the DT and 35 (range 26 to 508) days for the BTT cohort. All patients survived implantation; 30-day mortality was 22% (n = 2). The adverse event profile was encouraging, with no embolic neurologic events and minimal sepsis. Cumulative trial support time was 7.3 patient-years. CONCLUSIONS: The VentrAssist shows promise as a safe and reliable "third-generation" VAD. Having demonstrated potential as a DT and prolonged BTT device, extended clinical trials are warranted.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Idoso , Feminino , Humanos , Período Intraoperatório , Masculino , Projetos Piloto , Cuidados Pós-Operatórios , Resultado do Tratamento
12.
Inform Prim Care ; 14(3): 197-202, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17288706

RESUMO

Telecare services use information and communications technology (ICT) to support the provision of care to people in their own homes. This paper describes a pilot telecare service employed by Liverpool (UK) City Council to support a sample of their frail and elderly social services users. The pilot has been running for over two years and has been deployed for 21 individuals in Liverpool. In this paper we present the pilot system and provide real example cases which help to illustrate the benefits of such a system.


Assuntos
Telemedicina/instrumentação , Telemedicina/métodos , Idoso , Humanos , Satisfação do Paciente , Projetos Piloto , Reino Unido
13.
Inform Prim Care ; 14(3): 191-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17288705

RESUMO

The role of telecare systems is normally seen as identifying, and drawing attention to, situations of concern in the homes of service users. While this may currently be the primary reason for deploying such systems, the scope of telecare should not be limited to such an alarm generation role. The role of telecare in enhancing community-based care provision may be broadened by using similar, or identical, technology for providing relevant information to the carers of service users. In this paper we present a technical overview and discussion of an information provision approach to telecare which was trialled as one aspect of a pilot service in Liverpool, UK. The service used data collected by the telecare system to produce visual daily behavioural profiles and presented these to carers. The recipients for these profiles included social workers, occupational therapists and relatives of the service users. In this paper we discuss the visual profiles together with the benefits offered by such an information provision approach, including the perspective of a occupational therapist based in Liverpool.


Assuntos
Telemedicina/instrumentação , Telemedicina/métodos , Idoso , Cuidadores , Humanos , Terapia Ocupacional/métodos , Projetos Piloto , Reino Unido
14.
J Heart Lung Transplant ; 24(8): 1150-4, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16102463

RESUMO

The VentrAssist device left ventricular assist system, designed for permanent implantation, is a novel centrifugal pump with a hydrodynamically suspended rotor. The first human implant was into a 72-year-old man with New York Heart Association (NYHA) class IV heart failure due to idiopathic dilated cardiomyopathy. The implant and recovery were uneventful, and the patient survives at 17 months, is NYHA class II, and lives at home. This device shows promise in end-stage heart failure for permanent implantation and bridge to transplantation.


Assuntos
Cardiomiopatia Dilatada/cirurgia , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Disfunção Ventricular Esquerda/cirurgia , Idoso , Cardiomiopatia Dilatada/diagnóstico , Desenho de Equipamento , Segurança de Equipamentos , Seguimentos , Insuficiência Cardíaca/diagnóstico , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Medição de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico
15.
Anesth Analg ; 95(4): 805-12, table of contents, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12351249

RESUMO

UNLABELLED: Remifentanil may be beneficial in patients undergoing coronary artery bypass graft surgery, by promoting hemodynamic stability, reducing drug requirements, and attenuating the neurohumoral "stress response." We enrolled 77 cardiac surgical patients in a double-blinded, randomized trial and randomly allocated them to one of three groups: remifentanil infusion at 0.83 micro g. kg(-1). min(-1) (Group R); fentanyl bolus, small dose, at 12 micro g/kg (Group FLD); and fentanyl bolus, moderate dose, at 24 micro g/kg (Group FMD). We found a significant difference in the median time to tracheal extubation: Group FLD, 6.5 h; Group R, 7.3 h; and Group FMD, 9.7 h (P = 0.025). Group R patients had similar times to those of Groups FLD (P = 0.14) and FMD (P = 0.30). Group FLD patients had a longer length of hospital stay (P = 0.030). Patients in Group R had a significantly infrequent rate of hypertension but a frequent rate of hypotension (P < 0.01). The urinary cortisol excretion was larger in Group FLD patients (P < 0.0005), and urine flow was smaller (P < 0.0005). Remifentanil was associated with a propofol dose reduction (P = 0.0005) and a concomitant higher bispectral index (P = 0.032). Three Group FLD patients, but none in groups FMD and R, had postoperative myocardial infarctions (P = 0.032). Remifentanil has larger drug acquisition costs but does not increase the total hospital costs associated with cardiac surgery. IMPLICATIONS: Remifentanil did not significantly reduce the duration of tracheal intubation after cardiac surgery. Remifentanil, when compared with fentanyl (total doses of approximately 15 and 28 micro g/kg), blunts the hypertensive responses associated with cardiac surgery but is associated with more hypotension; when compared with fentanyl 15 micro g/kg, remifentanil reduces cortisol excretion. Larger-dose opioids (remifentanil 0.85 micro g. kg(-1). min(-1) or fentanyl 28 micro g/kg) were associated with a decreased rate of myocardial infarction after cardiac surgery.


Assuntos
Anestesia Intravenosa , Anestésicos Intravenosos , Procedimentos Cirúrgicos Cardíacos/economia , Procedimentos Cirúrgicos Cardíacos/métodos , Fentanila , Piperidinas , Idoso , Período de Recuperação da Anestesia , Anestesia Intravenosa/economia , Anestésicos Intravenosos/economia , Custos e Análise de Custo , Método Duplo-Cego , Eletrocardiografia/efeitos dos fármacos , Eletroencefalografia/efeitos dos fármacos , Feminino , Fentanila/economia , Hemodinâmica/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Piperidinas/economia , Complicações Pós-Operatórias/epidemiologia , Propofol , Estudos Prospectivos , Remifentanil , Respiração Artificial , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...